LED Driver, Meanwell, Hlg-60-36A manufacturer / supplier in China, offering Meanwell LED Power Supply Hlg-60h-36A, 25W 180mA 250mA 350mA 400mA 500mA 550mA 600mA 700 Cc 0-10V 1-10V LED Driver 0/1-10V Dimmable Driver 0-100% Full Dimming Range, Cc 0/1-10V Dimmable Driver 15W 100mA 120mA 200mA 250mA 300mA 350mA 400mA 0-10V LED Driver 1-10V 0-10V Dimming Driver 0-100% Full Dimming Range and so on.

(/ )

Supplier Homepage Product Waterproof power supply Meanwell LED Power Supply Hlg-60h-36A

Meanwell LED Power Supply Hlg-60h-36A

Purchase Qty.:
(Pieces)
1-49 50+
FOB Unit Price: US $32.5 US $32
Purchase Qty. (Pieces) FOB Unit Price
1-49 US $32.5
50+ US $32
Get Latest Price
Production Capacity: 50000PCS/Year
Transport Package: Carton
Payment Terms: L/C, T/T, D/P, Western Union, Paypal, Money Gram

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Model NO.: HLG-60-36A
  • Output Type: Single
  • Circuit Structure: Electronic Step-down Transformer
  • Power Supply Mode: Constant Current Source
  • In-Out: Step-down Type
  • Pack Sealing Size: 90~295VAC or 127~417VDC
  • Trademark: MEAN WELL
  • Origin: Jiangsu
  • Usage: Light, Industry, Vehicle
  • Driving Method: LED Constant Current
  • Certification: CE, RoHS, ISO9001
  • Modulation System: PFM
  • Power Supply Voltage: AC85-265
  • Brand: Meanwell
  • Specification: 0.8CUFT
  • HS Code: 8537109090
Product Description

Quick Details

Place of Origin:
Guangdong, China (Mainland)
Brand Name:
MEAN WELL
Model Number:
HLG-60H-36A
Output Power:
51 - 100W
Output Type:
Single
Input Voltage:
90~305VAC 127 ~ 431VDC
Output Voltage:
36V
Output Current:
0~1.70A
LED driver's dimension:
171*61.5*36.8mm (L*W*H)
Packing:
0.73Kg; 20pcs/15.6Kg/0.8CUFT
LED driver cooling type:
Cooling by free air convection
Working Temp.Humidity:
-40~ +70ºC , 20 ~ 95% RH
efficiency:
90.0%
Warranty:
5 years warranty'

Features:

  • Universal AC input / Full range (up to 305VAC)
  • Built-in active PFC function
  • Protections: Short circuit / Over current / Over voltage / Over temperature
  • Cooling by free air convection
  • OCP point adjustable through output cable or internal potentiometer
  • IP67 / IP65 design for indoor or outdoor installations
  • Class 2 Power Unit
  • Three in one dimming function (1~10Vdc or PWM signal or resistance)
  • Suitable for LED lighting and street lighting applications
  • Compliance to worldwide safety regulations for lighting
  • Suitable for dry / damp / wet locations
  • 7 years warranty 
Model Series:
 
HLG-60H-15() / HLG-60H-20() / HLG-60H-24() / HLG-60H-30() 
HLG-60H-36() / HLG-60H-42() / HLG-60H-48() / HLG-60H-54()
 
Model Type:HLG-60H
Blank:    IP67 rated. Cable for I/O connection.
A:    IP65 rated. Output voltage and constant current level can be adjusted through internal potentiometer.
B:     IP67 rated. Constant current level adjustable through output cable with 1~10Vdc or 10V PWM signal or resistance.
D(option):    IP67 rated. Timer dimming function, contact MEAN WELL for details.

 

MODELHLG-60H-15AHLG-60H-20AHLG-60H-24AHLG-60H-30A
OUTPUTDC VOLTAGE15V20V24V30V
RATED CURRENT4.0A3.0A2.5A2A
RATED POWER60W60W60W60W
RIPPLE & NOISE (max.)150mVp-p150mVp-p150mVp-p200mVp-p
VOLTAGE ADJ. RANGE13.5 ~ 17V17 ~ 22V22 ~ 27V27 ~ 33V
CURRENT ADJ. RANGECan be adjusted by internal potential meter or through output cable
2.4 ~ 4A1.8 ~ 3A1.5 ~ 2.5A1.2 ~ 2A
VOLTAGE TOLERANCE±2.0%±1.0%±1.0%±1.0%
LINE REGULATION±0.5%±0.5%±0.5%±0.5%
LOAD REGULATION±1.0%±1.0%±0.5%±0.5%
SETUP, RISE TIME500ms, 80ms / 115VAC at full load 1000ms, 80ms / 230VAC at full load
HOLD UP TIME (Typ.)16ms/230VAC 16ms/115VAC at full load
INPUTVOLTAGE RANGE90 ~ 305VAC /127 ~ 431VDC
FREQUENCY RANGE47~63Hz
POWER FACTORPF>0.98/115VAC, PF>0.95/230VAC, PF>0.92/277VAC at full load
EFFICIENCY (Typ.)87.50%89.00%89.50%90.00%
AC CURRENT0.43A / 115VAC        0.24A / 230VAC       0.23A / 277VAC
INRUSH CURRENT (Typ.)COLD START 55A(twidth=265μs measured at 50% Ipeak) at 230VAC
LEAKAGE CURRENT<0.75mA / 277VAC
PROTECTIONOVER CURRENT95 ~ 108%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
SHORT CIRCUITHiccup mode, recovers automatically after fault condition is removed.
OVER VOLTAGE18 ~ 24V23 ~ 30V28 ~ 35V35 ~ 43V
Protection type : Shut down and latch off o/p voltage, re-power on to recover
OVER TEMPERATURE 95ºC±10ºC(RTH2)
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
ENVIRONMENTWORKING TEMP.-40 ~ +70°C
WORKING HUMIDITY20 ~ 95% RH non-condensing
STORAGE TEMP., HUMIDITY-40~+80°C,10~95% RH
TEMP. COEFFICIENT±0.03%/ (0 ~ 50°C )
VIBRATION10 ~ 500Hz, 5G 12min./1cycle, period for 72min.each along X, Y,Z axes
SAFETY &EMCSAFETY STANDARDS UL8750, CSA C22.2 No. 250.0-08 (except for 48V, 54V), EN 61347 -1, EN61347-2-13 indep endent, IP65 or IP 67, J61347-1, J61347-2-13 approved ; design ref er to UL60950-1, T UV EN60950-1, EN60335-1
WITHSTAND VOLTAGEI/P-O/P:3.75KVAC     I/P-FG:2KVAC     O/P-FG:0.5KVAC
ISOLATION RESISTANCEI/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
EMC EMISSIONCompliance to EN55015, EN61000-3-2 Class C (≥60% load) ; EN61000-3-3
EMC IMMUNITYCompliance to EN61000-4-2,3,4,5,6,8,11; EN61547, EN55024, light industry level (surge 4KV), criteria A
EMS IMMUNITYCompliance to EN61000-4-2,3,4,5,6,8,11; EN61547, EN55024, light industry level (surge 4KV), criteria A
OTHERSMTBF338K hrs min. MIL-HDBK-217F (25ºC)
DIMENSION171*61.5*36.8mm (L*W*H)
PACKING0.73Kg; 20pcs/15.6Kg/0.9CUFT
 
MODELHLG-60H-36AHLG-60H-42AHLG-60H-48AHLG-60H-54A
OUTPUTDC VOLTAGE36V42V48V54V
RATED CURRENT1.7A1.45A1.3A1.15A
RATED POWER61.2W60.9W62.4W62.1W
RIPPLE & NOISE (max.)200mVp-p300mVp-p300mVp-p300mVp-p
VOLTAGE ADJ. RANGE33 ~ 40V40 ~ 46V44 ~ 53V49 ~ 58V
CURRENT ADJ. RANGECan be adjusted by internal potential meter or through output cable
1 ~ 1.7A0.87 ~ 1.45A0.78 ~ 1.3A0.69 ~ 1.15A
VOLTAGE TOLERANCE±1.0%±1.0%±1.0%±1.0%
LINE REGULATION±0.5%±0.5%±0.5%±0.5%
LOAD REGULATION±0.5%±0.5%±0.5%±0.5%
SETUP, RISE TIME500ms, 80ms / 115VAC at full load 1000ms, 80ms / 230VAC at full load
HOLD UP TIME (Typ.)16ms/230VAC 16ms/115VAC at full load
INPUTVOLTAGE RANGE90 ~ 305VAC /127 ~ 431VDC
FREQUENCY RANGE47~63Hz
POWER FACTORPF>0.98/115VAC, PF>0.95/230VAC, PF>0.92/277VAC at full load
EFFICIENCY (Typ.)90.00%90.00%90.50%90.50%
AC CURRENT0.43A / 115VAC        0.24A / 230VAC       0.23A / 277VAC
INRUSH CURRENT (Typ.)COLD START 55A(twidth=265μs measured at 50% Ipeak) at 230VAC
LEAKAGE CURRENT<0.75mA / 277VAC
PROTECTIONOVER CURRENT95 ~ 108%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
SHORT CIRCUITHiccup mode, recovers automatically after fault condition is removed.
OVER VOLTAGE41 ~ 49V48 ~ 58V54 ~ 65V59 ~ 68V
Protection type : Shut down and latch off o/p voltage, re-power on to recover
OVER TEMPERATURE 95ºC±10ºC(RTH2)
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
ENVIRONMENTWORKING TEMP.-40 ~ +70°C
WORKING HUMIDITY20 ~ 95% RH non-condensing
STORAGE TEMP., HUMIDITY-40~+80°C,10~95% RH
TEMP. COEFFICIENT±0.03%/ (0 ~ 50°C )
VIBRATION10 ~ 500Hz, 5G 12min./1cycle, period for 72min.each along X, Y,Z axes
SAFETY &EMCSAFETY STANDARDS UL8750, CSA C22.2 No. 250.0-08 (except for 48V, 54V), EN 61347 -1, EN61347-2-13 indep endent, IP65 or IP 67, J61347-1, J61347-2-13 approved ; design ref er to UL60950-1, T UV EN60950-1, EN60335-1
WITHSTAND VOLTAGEI/P-O/P:3.75KVAC     I/P-FG:2KVAC     O/P-FG:0.5KVAC
ISOLATION RESISTANCEI/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
EMC EMISSIONCompliance to EN55015, EN61000-3-2 Class C (≥60% load) ; EN61000-3-3
EMC IMMUNITYCompliance to EN61000-4-2,3,4,5,6,8,11; EN61547, EN55024, light industry level (surge 4KV), criteria A
EMS IMMUNITYCompliance to EN61000-4-2,3,4,5,6,8,11; EN61547, EN55024, light industry level (surge 4KV), criteria A
OTHERSMTBF338K hrs min. MIL-HDBK-217F (25ºC)
DIMENSION171*61.5*36.8mm (L*W*H)
PACKING0.73Kg; 20pcs/15.6Kg/0.9CUFT
NOTES1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Please refer to " DRIVING METHODS OF LED MODULE "
5. Derating may be needed under low input voltages. Please check the static characteristics for more details.
6. A type only.
7. Safety and EMC design refer to EN60598-1, CNS15233, GB7000.1, FCC part18.
8. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
9. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
10. Refer to warranty statement.
11. To fulfill requirements of latest ErP regulation for lighting sixtures, this LED power suppl can only be used behind a switch without permanently connected to the mains.

 

Meanwell LED Power Supply Hlg-60h-36AMeanwell LED Power Supply Hlg-60h-36AMeanwell LED Power Supply Hlg-60h-36AMeanwell LED Power Supply Hlg-60h-36A
 