MODEL | HLG-60H-15A | HLG-60H-20A | HLG-60H-24A | HLG-60H-30A |
OUTPUT | DC VOLTAGE | 15V | 20V | 24V | 30V |
RATED CURRENT | 4.0A | 3.0A | 2.5A | 2A |
RATED POWER | 60W | 60W | 60W | 60W |
RIPPLE & NOISE (max.) | 150mVp-p | 150mVp-p | 150mVp-p | 200mVp-p |
VOLTAGE ADJ. RANGE | 13.5 ~ 17V | 17 ~ 22V | 22 ~ 27V | 27 ~ 33V |
CURRENT ADJ. RANGE | Can be adjusted by internal potential meter or through output cable |
2.4 ~ 4A | 1.8 ~ 3A | 1.5 ~ 2.5A | 1.2 ~ 2A |
VOLTAGE TOLERANCE | ±2.0% | ±1.0% | ±1.0% | ±1.0% |
LINE REGULATION | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
LOAD REGULATION | ±1.0% | ±1.0% | ±0.5% | ±0.5% |
SETUP, RISE TIME | 500ms, 80ms / 115VAC at full load 1000ms, 80ms / 230VAC at full load |
HOLD UP TIME (Typ.) | 16ms/230VAC 16ms/115VAC at full load |
INPUT | VOLTAGE RANGE | 90 ~ 305VAC /127 ~ 431VDC |
FREQUENCY RANGE | 47~63Hz |
POWER FACTOR | PF>0.98/115VAC, PF>0.95/230VAC, PF>0.92/277VAC at full load |
EFFICIENCY (Typ.) | 87.50% | 89.00% | 89.50% | 90.00% |
AC CURRENT | 0.43A / 115VAC 0.24A / 230VAC 0.23A / 277VAC |
INRUSH CURRENT (Typ.) | COLD START 55A(twidth=265μs measured at 50% Ipeak) at 230VAC |
LEAKAGE CURRENT | <0.75mA / 277VAC |
PROTECTION | OVER CURRENT | 95 ~ 108% |
Protection type : Constant current limiting, recovers automatically after fault condition is removed |
SHORT CIRCUIT | Hiccup mode, recovers automatically after fault condition is removed. |
OVER VOLTAGE | 18 ~ 24V | 23 ~ 30V | 28 ~ 35V | 35 ~ 43V |
Protection type : Shut down and latch off o/p voltage, re-power on to recover |
OVER TEMPERATURE | 95ºC±10ºC(RTH2) |
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down |
ENVIRONMENT | WORKING TEMP. | -40 ~ +70°C |
WORKING HUMIDITY | 20 ~ 95% RH non-condensing |
STORAGE TEMP., HUMIDITY | -40~+80°C,10~95% RH |
TEMP. COEFFICIENT | ±0.03%/ (0 ~ 50°C ) |
VIBRATION | 10 ~ 500Hz, 5G 12min./1cycle, period for 72min.each along X, Y,Z axes |
SAFETY &EMC | SAFETY STANDARDS | UL8750, CSA C22.2 No. 250.0-08 (except for 48V, 54V), EN 61347 -1, EN61347-2-13 indep endent, IP65 or IP 67, J61347-1, J61347-2-13 approved ; design ref er to UL60950-1, T UV EN60950-1, EN60335-1 |
WITHSTAND VOLTAGE | I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC |
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH |
EMC EMISSION | Compliance to EN55015, EN61000-3-2 Class C (≥60% load) ; EN61000-3-3 |
EMC IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, EN55024, light industry level (surge 4KV), criteria A |
EMS IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, EN55024, light industry level (surge 4KV), criteria A |
OTHERS | MTBF | 338K hrs min. MIL-HDBK-217F (25ºC) |
DIMENSION | 171*61.5*36.8mm (L*W*H) |
PACKING | 0.73Kg; 20pcs/15.6Kg/0.9CUFT |
|
MODEL | HLG-60H-36A | HLG-60H-42A | HLG-60H-48A | HLG-60H-54A |
OUTPUT | DC VOLTAGE | 36V | 42V | 48V | 54V |
RATED CURRENT | 1.7A | 1.45A | 1.3A | 1.15A |
RATED POWER | 61.2W | 60.9W | 62.4W | 62.1W |
RIPPLE & NOISE (max.) | 200mVp-p | 300mVp-p | 300mVp-p | 300mVp-p |
VOLTAGE ADJ. RANGE | 33 ~ 40V | 40 ~ 46V | 44 ~ 53V | 49 ~ 58V |
CURRENT ADJ. RANGE | Can be adjusted by internal potential meter or through output cable |
1 ~ 1.7A | 0.87 ~ 1.45A | 0.78 ~ 1.3A | 0.69 ~ 1.15A |
VOLTAGE TOLERANCE | ±1.0% | ±1.0% | ±1.0% | ±1.0% |
LINE REGULATION | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
LOAD REGULATION | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
SETUP, RISE TIME | 500ms, 80ms / 115VAC at full load 1000ms, 80ms / 230VAC at full load |
HOLD UP TIME (Typ.) | 16ms/230VAC 16ms/115VAC at full load |
INPUT | VOLTAGE RANGE | 90 ~ 305VAC /127 ~ 431VDC |
FREQUENCY RANGE | 47~63Hz |
POWER FACTOR | PF>0.98/115VAC, PF>0.95/230VAC, PF>0.92/277VAC at full load |
EFFICIENCY (Typ.) | 90.00% | 90.00% | 90.50% | 90.50% |
AC CURRENT | 0.43A / 115VAC 0.24A / 230VAC 0.23A / 277VAC |
INRUSH CURRENT (Typ.) | COLD START 55A(twidth=265μs measured at 50% Ipeak) at 230VAC |
LEAKAGE CURRENT | <0.75mA / 277VAC |
PROTECTION | OVER CURRENT | 95 ~ 108% |
Protection type : Constant current limiting, recovers automatically after fault condition is removed |
SHORT CIRCUIT | Hiccup mode, recovers automatically after fault condition is removed. |
OVER VOLTAGE | 41 ~ 49V | 48 ~ 58V | 54 ~ 65V | 59 ~ 68V |
Protection type : Shut down and latch off o/p voltage, re-power on to recover |
OVER TEMPERATURE | 95ºC±10ºC(RTH2) |
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down |
ENVIRONMENT | WORKING TEMP. | -40 ~ +70°C |
WORKING HUMIDITY | 20 ~ 95% RH non-condensing |
STORAGE TEMP., HUMIDITY | -40~+80°C,10~95% RH |
TEMP. COEFFICIENT | ±0.03%/ (0 ~ 50°C ) |
VIBRATION | 10 ~ 500Hz, 5G 12min./1cycle, period for 72min.each along X, Y,Z axes |
SAFETY &EMC | SAFETY STANDARDS | UL8750, CSA C22.2 No. 250.0-08 (except for 48V, 54V), EN 61347 -1, EN61347-2-13 indep endent, IP65 or IP 67, J61347-1, J61347-2-13 approved ; design ref er to UL60950-1, T UV EN60950-1, EN60335-1 |
WITHSTAND VOLTAGE | I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC |
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH |
EMC EMISSION | Compliance to EN55015, EN61000-3-2 Class C (≥60% load) ; EN61000-3-3 |
EMC IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, EN55024, light industry level (surge 4KV), criteria A |
EMS IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, EN55024, light industry level (surge 4KV), criteria A |
OTHERS | MTBF | 338K hrs min. MIL-HDBK-217F (25ºC) |
DIMENSION | 171*61.5*36.8mm (L*W*H) |
PACKING | 0.73Kg; 20pcs/15.6Kg/0.9CUFT |
NOTES | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Please refer to " DRIVING METHODS OF LED MODULE " 5. Derating may be needed under low input voltages. Please check the static characteristics for more details. 6. A type only. 7. Safety and EMC design refer to EN60598-1, CNS15233, GB7000.1, FCC part18. 8. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time. 9. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. 10. Refer to warranty statement. 11. To fulfill requirements of latest ErP regulation for lighting sixtures, this LED power suppl can only be used behind a switch without permanently connected to the mains. |